Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Vox Sang ; 115(8): 802-812, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32633825

RESUMO

BACKGROUND AND OBJECTIVES: Patient blood (more accurately: haemoglobin, Hb) management (PBM) aims to optimize endogenous Hb production and to minimize iatrogenic Hb loss while maintaining patient safety and optimal effectiveness of medical interventions. PBM was adopted as policy for patients by the World Health Organization (WHO), and, all the more, should be applied to healthy donors. MATERIALS AND METHODS: Observational data from 489 bone marrow (BM) donors were retrospectively analysed, and principles of patient blood management were applied to healthy volunteer BM donations. RESULTS AND CONCLUSION: We managed to render BM aspiration safe for donors, notably completely avoiding the collection of autologous blood units and blood transfusions through iron management, establishment and curation of high-yield aspiration technique, limitation of collection volume to 1·5% of donor body weight and development of volume prediction algorithms for the requested cell dose.


Assuntos
Medula Óssea , Doadores de Tecidos , Coleta de Tecidos e Órgãos/métodos , Transplante de Medula Óssea , Feminino , Humanos , Masculino , Segurança do Paciente , Estudos Retrospectivos , Transplante de Células-Tronco
2.
J Transl Med ; 15(1): 174, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28800741

RESUMO

BACKGROUND: Red blood cell (RBC) depletion is a standard graft manipulation technique for ABO-incompatible bone marrow (BM) transplants. The BM processing module for Spectra Optia, "BMC", was previously introduced. We here report the largest series to date of routine quality data after performing 50 clinical-scale RBC-depletions. METHODS: Fifty successive RBC-depletions from autologous (n = 5) and allogeneic (n = 45) BM transplants were performed with the Spectra Optia BMC apheresis suite. Product quality was assessed before and after processing for volume, RBC and leukocyte content; RBC-depletion and stem cell (CD34+ cells) recovery was calculated there from. Clinical engraftment data were collected from 26/45 allogeneic recipients. RESULTS: Median RBC removal was 98.2% (range 90.8-99.1%), median CD34+ cell recovery was 93.6%, minimum recovery being 72%, total product volume was reduced to 7.5% (range 4.7-23.0%). Products engrafted with expected probability and kinetics. Performance indicators were stable over time. DISCUSSION: Spectra Optia BMC is a robust and efficient technology for RBC-depletion and volume reduction of BM, providing near-complete RBC removal and excellent CD34+ cell recovery.


Assuntos
Remoção de Componentes Sanguíneos/métodos , Medula Óssea/metabolismo , Eritrócitos/metabolismo , Antígenos CD34/metabolismo , Transplante de Medula Óssea , Linhagem da Célula , Estudos de Viabilidade , Hematopoese , Humanos , Transplante Homólogo
3.
Haematologica ; 101(8): 985-94, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27175026

RESUMO

To circumvent donor-to-donor heterogeneity which may lead to inconsistent results after treatment of acute graft-versus-host disease with mesenchymal stromal cells generated from single donors we developed a novel approach by generating these cells from pooled bone marrow mononuclear cells of 8 healthy "3(rd)-party" donors. Generated cells were frozen in 209 vials and designated as mesenchymal stromal cell bank. These vials served as a source for generation of clinical grade mesenchymal stromal cell end-products, which exhibited typical mesenchymal stromal cell phenotype, trilineage differentiation potential and at later passages expressed replicative senescence-related markers (p21 and p16). Genetic analysis demonstrated their genomic stability (normal karyotype and a diploid pattern). Importantly, clinical end-products exerted a significantly higher allosuppressive potential than the mean allosuppressive potential of mesenchymal stromal cells generated from the same donors individually. Administration of 81 mesenchymal stromal cell end-products to 26 patients with severe steroid-resistant acute graft-versus-host disease in 7 stem cell transplant centers who were refractory to many lines of treatment, induced a 77% overall response at the primary end point (day 28). Remarkably, although the cohort of patients was highly challenging (96% grade III/IV and only 4% grade II graft-versus-host disease), after treatment with mesenchymal stromal cell end-products the overall survival rate at two years follow up was 71±11% for the entire patient cohort, compared to 51.4±9.0% in graft-versus-host disease clinical studies, in which mesenchymal stromal cells were derived from single donors. Mesenchymal stromal cell end-products may, therefore, provide a novel therapeutic tool for the effective treatment of severe acute graft-versus-host disease.


Assuntos
Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/terapia , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Doadores de Tecidos , Adolescente , Adulto , Células da Medula Óssea , Técnicas de Cultura de Células , Diferenciação Celular , Proliferação de Células , Criança , Pré-Escolar , Resistência a Medicamentos , Feminino , Doença Enxerto-Hospedeiro/etiologia , Doença Enxerto-Hospedeiro/mortalidade , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Terapia de Imunossupressão , Lactente , Masculino , Células-Tronco Mesenquimais/citologia , Pessoa de Meia-Idade , Prognóstico , Índice de Gravidade de Doença , Esteroides/uso terapêutico , Análise de Sobrevida , Resultado do Tratamento , Adulto Jovem
4.
J Transl Med ; 14: 76, 2016 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-26983643

RESUMO

BACKGROUND: Automation of cell therapy manufacturing promises higher productivity of cell factories, more economical use of highly-trained (and costly) manufacturing staff, facilitation of processes requiring manufacturing steps at inconvenient hours, improved consistency of processing steps and other benefits. One of the most broadly disseminated engineered cell therapy products is immunomagnetically selected CD34+ hematopoietic "stem" cells (HSCs). METHODS: As the clinical GMP-compliant automat CliniMACS Prodigy is being programmed to perform ever more complex sequential manufacturing steps, we developed a CD34+ selection module for comparison with the standard semi-automatic CD34 "normal scale" selection process on CliniMACS Plus, applicable for 600 × 10(6) target cells out of 60 × 10(9) total cells. Three split-validation processings with healthy donor G-CSF-mobilized apheresis products were performed; feasibility, time consumption and product quality were assessed. RESULTS: All processes proceeded uneventfully. Prodigy runs took about 1 h longer than CliniMACS Plus runs, albeit with markedly less hands-on operator time and therefore also suitable for less experienced operators. Recovery of target cells was the same for both technologies. Although impurities, specifically T- and B-cells, were 5 ± 1.6-fold and 4 ± 0.4-fold higher in the Prodigy products (p = ns and p = 0.013 for T and B cell depletion, respectively), T cell contents per kg of a virtual recipient receiving 4 × 10(6) CD34+ cells/kg was below 10 × 10(3)/kg even in the worst Prodigy product and thus more than fivefold below the specification of CD34+ selected mismatched-donor stem cell products. The products' theoretical clinical usability is thus confirmed. CONCLUSIONS: This split validation exercise of a relatively short and simple process exemplifies the potential of automatic cell manufacturing. Automation will further gain in attractiveness when applied to more complex processes, requiring frequent interventions or handling at unfavourable working hours, such as re-targeting of T-cells.


Assuntos
Antígenos CD34/metabolismo , Automação , Remoção de Componentes Sanguíneos/métodos , Terapia Baseada em Transplante de Células e Tecidos , Células-Tronco Hematopoéticas/citologia , Citometria de Fluxo , Humanos , Reprodutibilidade dos Testes
5.
Cytotherapy ; 17(10): 1465-71, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25981397

RESUMO

BACKGROUND AIMS: Immunomagnetic enrichment of CD34+ hematopoietic "stem" cells (HSCs) using paramagnetic nanobead coupled CD34 antibody and immunomagnetic extraction with the CliniMACS plus system is the standard approach to generating T-cell-depleted stem cell grafts. Their clinical beneficence in selected indications is established. Even though CD34+ selected grafts are typically given in the context of a severely immunosuppressive conditioning with anti-thymocyte globulin or similar, the degree of T-cell depletion appears to affect clinical outcomes and thus in addition to CD34 cell recovery, the degree of T-cell depletion critically describes process quality. An automatic immunomagnetic cell processing system, CliniMACS Prodigy, including a protocol for fully automatic CD34+ cell selection from apheresis products, was recently developed. We performed a formal process validation to support submission of the protocol for CE release, a prerequisite for clinical use of Prodigy CD34+ products. METHODS: Granulocyte-colony stimulating factor-mobilized healthy-donor apheresis products were subjected to CD34+ cell selection using Prodigy with clinical reagents and consumables and advanced beta versions of the CD34 selection software. Target and non-target cells were enumerated using sensitive flow cytometry platforms. RESULTS: Nine successful clinical-scale CD34+ cell selections were performed. Beyond setup, no operator intervention was required. Prodigy recovered 74 ± 13% of target cells with a viability of 99.9 ± 0.05%. Per 5 × 10E6 CD34+ cells, which we consider a per-kilogram dose of HSCs, products contained 17 ± 3 × 10E3 T cells and 78 ± 22 × 10E3 B cells. CONCLUSIONS: The process for CD34 selection with Prodigy is robust and labor-saving but not time-saving. Compared with clinical CD34+ selected products concurrently generated with the predecessor technology, product properties, importantly including CD34+ cell recovery and T-cell contents, were not significantly different. The automatic system is suitable for routine clinical application.


Assuntos
Antígenos CD34/imunologia , Remoção de Componentes Sanguíneos/métodos , Separação Celular/métodos , Células-Tronco Hematopoéticas/citologia , Separação Imunomagnética/métodos , Soro Antilinfocitário/imunologia , Automação Laboratorial , Linfócitos B/imunologia , Células Cultivadas , Citometria de Fluxo , Fator Estimulador de Colônias de Granulócitos/imunologia , Transplante de Células-Tronco Hematopoéticas/métodos , Células-Tronco Hematopoéticas/imunologia , Humanos , Depleção Linfocítica/métodos , Linfócitos T/imunologia
6.
Transfusion ; 55(6): 1275-82, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25647556

RESUMO

BACKGROUND: Red blood cell (RBC) depletion is a standard technique for preparation of ABO-incompatible bone marrow transplants (BMTs). Density centrifugation or apheresis are used successfully at clinical scale. The advent of a bone marrow (BM) processing module for the Spectra Optia (Terumo BCT) provided the initiative to formally compare our standard technology, the COBE2991 (Ficoll, manual, "C") with the Spectra Optia BMP (apheresis, semiautomatic, "O"), the Sepax II NeatCell (Ficoll, automatic, "S"), the Miltenyi CliniMACS Prodigy density gradient separation system (Ficoll, automatic, "P"), and manual Ficoll ("M"). C and O handle larger product volumes than S, P, and M. STUDY DESIGN AND METHODS: Technologies were assessed for RBC depletion, target cell (mononuclear cells [MNCs] for buffy coats [BCs], CD34+ cells for BM) recovery, and cost/labor. BC pools were simultaneously purged with C, O, S, and P; five to 18 BM samples were sequentially processed with C, O, S, and M. RESULTS: Mean RBC removal with C was 97% (BCs) or 92% (BM). From both products, O removed 97%, and P, S, and M removed 99% of RBCs. MNC recovery from BC (98% C, 97% O, 65% P, 74% S) or CD34+ cell recovery from BM (92% C, 90% O, 67% S, 70% M) were best with C and O. Polymorphonuclear cells (PMNs) were depleted from BCs by P, S, and C, while O recovered 50% of PMNs. Time savings compared to C or M for all tested technologies are considerable. CONCLUSION: All methods are in principle suitable and can be selected based on sample volume, available technology, and desired product specifications beyond RBC depletion and MNC and/or CD34+ cell recovery.


Assuntos
Buffy Coat/citologia , Remoção de Componentes Sanguíneos/métodos , Separação Celular/métodos , Centrifugação com Gradiente de Concentração/métodos , Eritrócitos , Células Sanguíneas , Remoção de Componentes Sanguíneos/economia , Remoção de Componentes Sanguíneos/instrumentação , Incompatibilidade de Grupos Sanguíneos/prevenção & controle , Células da Medula Óssea , Separação Celular/economia , Separação Celular/instrumentação , Centrifugação com Gradiente de Concentração/economia , Centrifugação com Gradiente de Concentração/instrumentação , Desenho de Equipamento , Volume de Eritrócitos , Ficoll , Hematócrito , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...